RAD restriction ED2285

Explain
Candidate screen (advisory)
Search Results (3 found)
RAD V1.6
(Annex 2B) Local and Cross-border Capacity and Structural Rules (3 found)

ED2285

RAD Code

ED2285

Valid From

2604 [16 APR 2026]

Valid Until

UFN

Point or Airspace

TIVUN

Time Applicability

04:00-22:30 (03:00-21:30)

Categorisation

S

Utilization
NOT AVBL FOR TFC
1.VIA TIVUN & ABV FL245 AT TIVUN EXC
a.VIA (TIVUN DCT ESAMA DCT OSBIT DCT KOMIB) AND-THEN VIA (NIKUS, ODOMO, OKG, VEMUT)
b.VIA (TIVUN DCT ESAMA DCT OSBIT DCT BOREP) AND-THEN VIA (ENITA, ARMUT)
c.VIA (TIVUN DCT ESAMA DCT OSBIT DCT BARSU DCT (DEXIT, EKSOS, MOOCE))
d.VIA (TIVUN DCT ESAMA DCT OSBIT DCT TENLO) AND-THEN VIA LAMSI
e.VIA (TIVUN DCT DODEN DCT TABUM) AND-THEN VIA (GIGET, OMOGI, FOLWU, HAREM)
f.VIA (TIVUN DCT TESGA) AND-THEN
i)VIA (TESGA Z719 ETOLU)
ii)VIA (TESGA Z10 RUDUS)
iii)VIA (TESGA L603 BOMBI Z120 OLKAS)
g.VIA ((MASEK, SWALM) DCT TIVUN) & ABV FL335 AT (MASEK, SWALM)
Operational Goal
Free Route Flow restriction to enforce shorter but also segregated routings and ensure certain DCT sequence allowing FL changes, optimum tactical handling and respecting LoA conditions.
Listed DCTs without FL are part of EDUUFRAW (all DCTs H24, MIN FL245), except in 1.d. OSBIT DCT TENLO refers to RAD ANNEX 3B (MIN FL325).
ATC Unit

EDUUUAC

NAS/FAB

ED

Release Date

06 MAR 2026

ED2726

RAD Code

ED2726

Valid From

2604 [16 APR 2026]

Valid Until

UFN

Point or Airspace

ESAMA

Time Applicability

04:00-22:30 (03:00-21:30)

Categorisation

C

Utilization
NOT AVBL FOR TFC
ABV FL245 AT ESAMA EXC VIA ((TIVUN, GMH) DCT ESAMA)
Operational Goal
Free Route Flow restriction to enforce shorter routing and ensure certain DCT sequence allowing FL changes, optimum tactical handling and respecting LoA conditions.
All DCTs are part of H24 EDUUFRAW above FL245.
Note, ED2283 (GMH) and ED2285 (TIVUN) limit downstream connections.
ATC Unit

EDUUUAC

NAS/FAB

ED

Release Date

06 MAR 2026

EDYX1175

RAD Code

EDYX1175

Valid From

2604 [16 APR 2026]

Valid Until

UFN

Point or Airspace

EDGTTIVUN

Time Applicability

H24 ---------- 05:00-23:00 (04:00-22:00)

Categorisation

S

Utilization
NOT AVBL FOR TFC
1.VIA EDYYHRHR AND-THEN VIA EDGTTIVUN
EXC
a.VIA (DODEN, TIVUN)
b.VIA (HEFME Z841 GMH)
c.VIA (ONUNE DCT GMH)
----------
NOT AVBL FOR TFC
1.VIA EDYYBUTA AND-THEN VIA EDGTTIVUN
2.VIA (EDYYHCEL, EDYYHSOL) AND-THEN VIA EDGTTIVUN
Operational Goal
Free Route Flow restriction via Gate to allow additional x-border FRA options and to ensure LoA conditions.
For segments downstream see the respective FRA Flow restrictions (for DODEN-ED2578, GMH-ED2283, TIVUN-ED2285).
------
To avoid unusual sector sequence.
1.Eastbound traffic via the Brussels sectors of Maastricht UAC shall file via MATUG, LIRSU or cross-border FRA options across gate EDGTLIRSU.
2.Southbound traffic via the Celle / Solling sector of Maastricht UAC shall file via XAROL, OTMON or cross-border FRA options across gate EDGTXAROL / EDGTOTMON.
ATC Unit

EDUUUAC, EDYYUAC

NAS/FAB

ED,YX

Release Date

06 MAR 2026

Advisory only. This screens your route against restrictions we could structurally parse — it can never tell you a route is clean. IFPS validation is the only authoritative check.

Get in touch with us

Subscribe to receive updates about new features and improvements.

Contact Information

Feel free to reach out with any questions or feedback.


© 2026 RAD Restrictions. All rights reserved. By subscribing, you agree to receive updates from RAD Restrictions.
An unhandled error has occurred. Reload 🗙